Pin
Signal name
Meaning
10
DI/DO9
Digital input/output 9 (rapid input)
11
M
Ground
12
DI/DO10
Digital input/output 10 (rapid input)
13
DI/DO11
Digital input/output 11 (rapid input)
14
M
Ground
An open input is interpreted as "low".
Note
Terminal M1 must be connected for the digital inputs (DI) 0 to 3 and 16/17 to function. This
can be done as follows:
● Connect the ground reference of the digital inputs.
● Jumper to terminal M: This removes the electrical isolation for these digital inputs.
Table 7-118 Technical data for X122
Parameter
Value
Current consumption
Typical: 10 mA at 24 V DC
Galvanic isolation
The reference potential is terminal M1
As an input
Voltage
-3 V to 30 V
Current consumption
Typical: 10 mA at 24 V DC
Signal level (including ripple)
High signal level: 15 V to 30 V
Low signal level: -3 V to 5 V
Signal propagation times
Inputs / "fast inputs":
L → H: approx. 50 μs/5 μs
H → L: approx. 100 μs/50 μs
As an output
Voltage
24 V DC
Max. load current
Per output: 500 mA continuous short circuit-proof
Connectable components
7.8 NX10.3
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3