Switch S2
6FKDOWHU6
Switch position: "ON" is at the top.
Table 7-26
Switch S2 is set as delivered
1
2
3
4
5
6
7
8
9
10
Meaning
ON
ON PLC I/O Interface
OFF OFF OFF OFF OFF OFF OFF OFF
PROFINET address "0"
The two switches S2-9 and S2-10 must remain set to "ON".
The switches S2-1 to S2-8 define the PROFINET address. For a SINUMERIK 828D,
the address "64" must always be assigned to the MCP.
Table 7-27
Settings of switch S2
1
2
3
4
5
6
7
8
9
10
Meaning
ON
ON
ON
OFF OFF OFF OFF OFF OFF
OFF
PROFINET address "64"
7.2.4
Parameterization
The specifications for assigning input and output bytes listed in the tables are set as standard
addresses in the PLC by setting the following machine data:
MD12986 PLC_DEACT_IMAGE_LADDR_IN[6] = -1
Standard input image
Table 7-28
Input image MCP 310C PN
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
EB112
* NC
Stop
Spindle -
Spindle
100%
S
Single
block
JOG
MDA
AUTO
EB113
NC
Start
Spindle
right
* Spindle
stop
Spindle
left
Keyswitch
position 3
REF
REP
Teach
IN
EB114
Feed
Start
* Feed
Stop
INC VAR
Keyswitch
position 0
INC 1000
INC 100
INC 10
INC 1
Connectable components
7.2 MCP 310C PN
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
123