Application example
Example
Possible solution
The drive must brake as quickly as possible after the
Emergency Stop button has been pressed. It is not
permissible that the stationary motor undesirably re‐
starts.
● Select SS1 in the inverter via a fail-safe
digital input or via PROFIsafe.
Description
3.7 An overview of the principle of operation of the safety functions
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
38
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD