Inverter signal
Parameter
Included in the PROFI‐
safe telegram
Can be interconnec‐
ted with
F-DI
F-DO
Deselect SS1 (extended functions)
r9720.1
✓
✓
---
SAM/SBR active
r9723.16
---
---
---
Ready to switch on
r0052.0
---
---
---
ON/OFF1
r0054.0
---
---
---
Switching on the motor once SS1 is active
Procedure
To switch on the motor again once SS1 is active, proceed as follows:
1. Deselect SS1.
2. After deselecting SS1, wait until the inverter is "ready to switch on".
Alternatively: After deselecting SS1, wait a certain time before switching on. We
recommend a wait time of 200 ms.
3. Switch on the motor: ON/OFF1 = 1.
You have switched on the motor.
Operation
6.5 Safe Stop 1 (SS1)
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD
243