Configuration using the WBM
7.3 The menu items of the WBM
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
67
Reader parameters
If you have selected the "General Reader" parameter value in the "Identification
Devices/System" parameter, the reset parameters of the reader connected to the interface
are displayed in hexadecimal format in this area. You can find more detailed information on
this in section "Ident profile and Ident blocks, standard function for Ident systems
https://support.industry.siemens.com/cs/ww/en/ps/14970/man
)".
If you have set another parameter value in the "Ident device/system" parameter and
depending on the basic parameters set, you can configure the following reader parameters
in the "Reader parameters" parameter group.
Table 7- 5
Parameters in the "Reader parameters" parameter group
Parameter
Parameter value
Default value
Description
Presence check
On
Off (RF field on)
Off (RF field off)
On
On = As soon as there is a transponder in the
antenna field of the reader, its presence is re-
ported.
Off (RF field on) = the presence check in the FB
is suppressed. The antenna on the reader is
nevertheless turned on as long as it has not
been turned off by a command.
Off (RF field off) = the antenna is turned on only
when a command is sent and it then turns itself
off again.
HF power
1)
0.50 ... 5.00
1.00
1.25
Setting for the output power of the reader.
Reset error LED
On
Off
On
On = The flashing of the error LED on the read-
er is reset by each reset and by a new OPC
command.
Off = the error LED always indicates the last
error. The display can only be reset by turning
off the reader.
Off
After a successful com-
mand:
After a reset command
After a reset or a suc-
cessful command
Off = The flashing LED is not reset in the event
of an error, even by switching off the power
supply to the reader.
After a successful command = The flashing of
the LED in the event of an error is reset after
the successful execution of a command. This
only affects communication errors.
After a reset command = The flashing of the
LED in the event of an error is reset by a "in-
it_run" or "WRITE-CONFIG" with "Init"
(RESET).
After a reset or a successful command = The
flashing of the LED in the event of an error is
reset by a "init_run" or "WRITE-CONFIG" with
"Init" (RESET) or after the successful execution
of a command.
Max. number of tran-
sponders
1 ... 40
1
Number of transponders expected in the anten-
na field.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...