Service and maintenance
10.2 Error messages
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
141
"ER"
LED
Block (hex)
Error description
4x
0xE6FE8300 The parameter type is invalid.
4x
0xE6FE8400 Unknown parameter.
4x
0xE6FE8500 The command or the frame has an invalid format.
4x
0xE6FE8600 The inventory command failed.
4x
0xE6FE8700 Read access to the transponder has failed.
4x
0xE6FE8800 Write access to the transponder has failed.
4x
0xE6FE8900 Writing the EPC ID/UID on the transponder has failed.
4x
0xE6FE8A00 Enabling write protection on the transponder has failed.
4x
0xE6FE8B00 The "Kill" command failed.
--
0xE7FE0100 In this state, only the "Reset_Reader" command ("WRITE-CONFIG") is permitted.
--
0xE7FE0200 The "CMD" command code is not permitted.
--
0xE7FE0300 The "LEN_DATA" parameter of the command is too long and does not match the global data
reserved within the send data buffer (TXBUF).
--
0xE7FE0400 The receive data buffer (RXBUF) or the send data buffer (TXBUF) is too small, the buffer created
at TXBUF/RXBUF does not have the correct data type or the parameter "LEN_DATA" has a
negative value.
Possible cause / action to be taken:
•
Check whether the buffers TXBUF/RXBUF are at least as large as specified in "LEN_DATA".
•
With S7-1200/1500:
–
In the Ident profile, only an "Array of Byte" may be created for TXBUF and RXBUF.
–
In the "Reader_Status" block, only an "Array of Byte" or the corresponding data types
("IID_TAG_STATUS_XX_XXX" or "IID_READER_STATUS_XX_XXX") may be created
--
0xE7FE0500 Error message that informs you that only an "INIT" command is permitted as the next command.
All other commands are rejected.
--
0xE7FE0600 Wrong data record index of an acyclic data record
Permitted index is in the ranges "101 ... 108" and "-20401 ... -20418".
--
0xE7FE0700 The reader or communication module does not respond to "INIT" ("INIT_ACTIVE" is expected in
the cyclic status message).
The next steps:
•
Check the address parameter "LADDR".
--
0xE7FE0800 Timeout during "INIT" (60 seconds)
--
0xE7FE0900 Command repetition is not supported.
--
0xE7FE0A00 Error during the transfer of the PDU (Protocol Data Unit).
"--" means that the error is not displayed by the LEDs.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...