Configuring
6.2 Configuration via PROFIBUS
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
53
Parameter group "Module parameters" of the connected readers
In this parameter group, you can configure all module-specific parameters of the connected
readers. Please note that some of the following parameters are module-specific. For some
module types, not all parameters are displayed.
If no device is connected to interface X21, you need to assign an "Empty" module to this
interface.
Table 6- 3
Parameters of the parameter group "Module parameters" of the connected readers
Parameter
Parameter value
Default value
Description
User mode
Ident profile/RFID stand-
ard profile
FB 45
Ident profile/RFID
standard profile
With this parameter, you select the block:
•
Ident profile/RFID standard profile:
Single tag / multitag operation. The program
block for the Ident profile is used in the con-
troller.
•
FB 45:
Single tag mode. FB 45 is used in the con-
troller
MOBY mode
RF200/RF300/RF600;
MV400/MV500; MOBY
U/D normal addr.
RF200/RF300/RF60
0; MV400/MV500;
MOBY U/D normal
addr.
With this parameter, you set the mode of the
communication module.
•
RF200/RF300/RF600; MV400/500; MOBY
U/D normal addr.
Normal addressing: The transponder is ad-
dressed with physical addresses.
Transmission
speed
19.2 kBd
57.6 kBd
115.2 kBd
921.6 kBd
115.2 kBd
With this parameter, you set the data transmis-
sion speed between the communication module
and reader.
When an optical reader is connected: The
transmission speed selected here must match
the transmission speed selected for the reader.
Diagnostics
messages
None
Hard errors
Hard/soft errors
None
With this parameter, you determine the extent
to which the reader-related diagnostic interrupt
messages are to be reported.
•
None:
No alarms are generated.
•
Hard errors:
Critical hardware errors/faults are reported
by the S7 diagnostics.
•
Hard/soft errors:
Critical hardware faults and errors occurring
when processing commands are reported
by the S7 diagnostics.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...