Read/write
In the "Read/write" area, you can read out and overwrite the memory areas. You can access
pre-defined addresses (tag fields). Using the parameters, you can adapt the memory area
manually.
Table 7- 19 Description of the parameters of the tag fields
Parameter
Description
Start address
Value of the start address of the data to be read/written.
Value range
0 ... 65535 bytes
Length
Number of bytes to be read/written starting at the start address.
Value range
1 ... 1024 bytes
Data
Input boxes for the values (HEX format).
Possible characters
0 ... 9, A ... F
ASCII
Showing/hiding the ASCII view.
When the ASCII view is active, the data is shown additionally in ASCII
notation. You can edit the data both in the HEX format or in the ASCII
format.
You can choose between the two input modes "Overwrite" and "Insert".
Initialize data
Show/hide the view for initializing the data.
Using the initialization function, you can preset the data fields.
Next to the list of tag fields, the data of the selected memory area is displayed in HEX view.
With the "Read" button, the data is read from the transponder. The data read from the
transponder is highlighted in red to distinguish it from the data entered manually. If no values
are displayed, this means that no values have yet been read from the transponder.
Click the "Write" button to transfer the changed data to the transponder.
NOTICE
Reading/writing transponder data with an established connection to the controller
Note that, if a connection to the controller is established, the configuration of the readers is
performed via the controller. To enable transponder data to be read/written via the WBM,
the connected readers must have been initialized via the S7 controller beforehand.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...