Service and maintenance
10.2 Error messages
SIMATIC RF166C
144
Operating Instructions, 12/2019, C79000-G8976-C578-01
AutoId
status
OPC UA
status
AutoId
text
Error description
19
good
RF_COMMUNICATION_
ERROR
General transponder error
19
good
RF_COMMUNICATION_
ERROR
The transponder has too little power to execute the command.
19
good
RF_COMMUNICATION_
ERROR
The transponder signals a CRC error.
19
good
RF_COMMUNICATION_
ERROR
The selected frequency is not enabled.
19
good
RF_COMMUNICATION_
ERROR
The carrier signal is not activated.
19
good
RF_COMMUNICATION_
ERROR
General radio protocol error
20
good
DEVICE_FAULT
Fault in power supply
The power supply is very close to the low limit.
20
good
DEVICE_FAULT
Antenna errors
•
The antenna or the antenna cable is defective.
•
Error in the connection to the reader; the reader is not an-
swering (in PROFIBUS operation).
–
The cable between the communications module and
reader is wired incorrectly or there is a cable break
–
The 24 V supply voltage is not connected or is turned off
or has failed briefly
–
Automatic fuse on the communications module has
blown
–
Hardware defective
–
Another reader is in the vicinity and is active
–
There is a reflecting metal surface in the vicinity that is
disrupting the antenna field
–
Execute "init_run" after correcting the error
--
--
--
The selected antenna is not enabled.
--
OpcUa_
BadInva-
lidState
--
The command is not permitted in this status or is not supported.
Possible cause:
•
"INIT" was chained.
•
Command repetition was started without "Presence mode".
--
OpcUa_
BadOutOf
Range /
OpcUa_
Bad
Configura-
tion
Error
--
No or bad configuration data/parameters were transferred.
Possible cause:
•
You are accessing a read point that is not configured.
--
BadInvalid
Argument
--
A parameter is missing.
--
BadInvalid
Argument
--
The parameter has an invalid format.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...