Programming via OPC UA
9.2 OPC UA variables
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
109
9.2.6
Diagnosis
These variables serve diagnostics and tracking purposes of the plant via OPC UA.
Diagnostics - Presence
Table 9- 11 Presence
Path
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/Presence
Data type
UInt16
Access
R
Description
Shows the presence of transponders.
The prerequisite is that the reader supports "Presence" mode
and is operated in this mode, and that the option "Parallel" or
"Diagnostics" is set in the WBM.
Possible values
•
0: There is no transponder in the antenna field
•
1: There is at least one transponder in the antenna field
•
>1: Exact number of transponders (if supported by the read-
er)
Diagnostics - LastAccess
These variables supply various information on the last successful transponder access or
command.
Please note that these variables supply logically related information. With successful
transponder access, the contents of the "Time stamp" will be written last; all other supported
"LastAccess" variables are filled first. These variables can thus serve as a trigger for an OPC
UA client in order to query the other variable values.
If it is not possible to determine in time that variables can be queried completely by the client
before the next transponder access takes place and variables are written with new values
again from the process, usage is not possible. If this is not possible, use the
"AutoIdLastAccessEvent" events, which are also supported by the communication modules.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...