Programming via OPC UA
9.3 OPC UA events
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
121
Table 9- 34 Antenna
Data type
Int32
Description
The antenna via which the transponder was accessed with the
last command.
Possible values
Two-digit number
The first digit stands for the read point index, the second digit for
the antenna index within the read point.
Example:
•
Read point 1, antenna 1: 11
•
Read point 2, antenna 1: 21
Table 9- 35 CurrentPowerLevel
Data type
Int32
Description
Power with which the last command was executed on the tran-
sponder. This variable is only supported by UHF readers.
Possible values
Decimal number for the power in [dB]
Increment: 0.25 dB
•
0
•
5.00 ... 33.00
Table 9- 36 PC
Data type
UInt16
Description
Protocol Control Word of the transponder that was accessed last.
This variable is only supported by UHF readers.
Possible values
Example:
3000
Table 9- 37 Polarization
Data type
String
Description
Polarization with which the last command was executed on the
transponder. This variable is only supported by UHF readers.
Possible values
•
Default
•
Circular
•
Linear_vertical
•
Linear_horizontal
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...