Connecting
5.3 Connecting CM to functional ground
SIMATIC RF166C
36
Operating Instructions, 12/2019, C79000-G8976-C578-01
5.3.3
Mounting the CM on a non-conductive base
Requirement
Non-conductive base for mounting the module.
Required tools
You need the following tools to connect to the functional ground:
●
Screwdriver
●
Stripping tool
●
Crimp tool
Accessories required
To connect to functional ground with a non-conductive mounting base, you can need the
following accessories:
●
Fastening screw (M4) and washer
●
Cable lug suitable for M4 screws
●
Ground conductor cable (copper braid) with a minimum cross-section of 4 mm
2