Configuration using the WBM
7.3 The menu items of the WBM
SIMATIC RF166C
66
Operating Instructions, 12/2019, C79000-G8976-C578-01
Parameter
Parameter value
Default value
Description
RF300 general, fast
protocol
RF300 fast protocol
RF380R fast protocol
RF600
Freeport
Diagnostic
messages
None
Hard errors
Hard/soft errors
None
Shows which diagnostic messages have been
set in STEP 7 (cf. Section "Parameterization of
the diagnostics (Page 131)"):
•
None:
Apart from standard diagnostics, no other
alarms are generated.
•
Hard errors:
Critical hardware errors/faults are reported
by the S7 diagnostics.
•
Hard/soft errors
Critical hardware errors and errors that oc-
cur during command processing are report-
ed by the S7 diagnostics. The "Ext_Diag" bit
is set.
Read point name
--
--
In the text box, you can assign a name to the
read point(s) (for example, "Incoming goods
gate 5" or "Welding robot 21"). Note that the
name is required for addressing the reader via
OPC UA.
Transmission
speed
19.2 kBd
57.6 kBd
115.2 kBd
921.6 kBd
115.2 kBd /
921.6 kBd
Selection depends on the Ident device/system
being used. With this parameter, you set the
data transmission speed between the commu-
nication module and reader.
User mode
Ident profile/RFID stand-
ard profile
FB 45
Ident profile/RFID
standard profile
Shows which block has been set in STEP 7:
•
Ident profile/RFID standard profile:
The program block for the Ident profile/RFID
standard profile is used on the controller.
•
FB 45:
Single tag mode. FB 45
(PROFIBUS/PROFINET) is used in the con-
troller.
The parameter values of the basic parameters can be preset automatically using the
"Autoconfiguration" button. By pressing the button, the communication module automatically
identifies the device connected to the interface and sets the appropriate parameter values.
Using the "Update firmware" link, you jump to the "System - Reader firmware" menu item in
which you can update firmware for the connected reader.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...