Programming via OPC UA
9.1 Supported methods/functions
SIMATIC RF166C
104
Operating Instructions, 12/2019, C79000-G8976-C578-01
OPC UA variables
ExecuteScan
Read point scans for transponders.
SimaticIdentModelVersion
Version information of the supported SIMATIC Ident OPC UA model
CommonSettings
General settings
CodeTypes
Definition of the data type for all AutoID identifiers with methods or events.
•
Variable "LastScanData"
•
Diagnostics variable "Identifier"
•
Union "ScanData"
CodeTypesRWData
Definition of the data type of the "RWData" diagnostics variable
DeviceClock
Device clock of the communication module
RfidSettings
RFID-specific settings
MinRssi
Lowest accepted RSSI value of the antenna
This function is only supported by UHF readers.
RfPower
Radiated power of the antenna
Diagnosis
Diagnostics information
Presence
Presence of transponders
Diagnosis - LastAccess
Various information on the last successful transponder access or command
Client
Client interface via which the last transponder access took place.
Command
Command that was executed during the last transponder access operation.
Identifier
Transponder which was accessed with the last command.
Timestamp
Time of the last transponder access
RWData
Read/written data of the last command.
Only possible with commands for reading/writing the transponder memory.
Antenna
Antenna via which the transponder was accessed with the last command.
CurrentPowerLevel
Power with which the last command was executed on the transponder.
This function is only supported by UHF readers.
PC
Protocol Control Word of the transponder that was accessed last.
This function is only supported by UHF readers.
Polarization
Polarization with which the last command was executed on the transponder.
This function is only supported by UHF readers.
Strength
RSSI value with which the last command was executed on the transponder.
This function is only supported by UHF readers.
Diagnosis - Logbook
Various log information.
LastLogEntry
The last entry in the log.
LogColumns
The headers column of the log as formatted string
You can find the specified functions under the following path in the address area of a read
point:
●
DeviceSet > Readpoint_x1 > IOData
●
DeviceSet > Readpoint_x1 > RuntimeParameters
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...