Configuration using the WBM
7.3 The menu items of the WBM
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
73
Basic settings
You can make the basic settings for the OPC UA communication in the "Basic settings" area.
Select the "Interlock OPC" check box to disable the OPC UA communication.
Table 7- 9
Description of the parameters
Parameter
Description
Application name
Name of the OPC UA application of the server. The application name is re-
quired to identify the OPC UA namespace of the communication module and
should be unique for each communication module within the project.
The application name is part of the URL of the OPC UA server of the commu-
nication module.
Minimum
sampling interval
Minimum sampling interval at which the communication module samples the
process data.
Range of values: 10 .. 50 ms
Default setting: 50 ms
Default port
Here you can change the port number of the application. As default, port num-
ber 4840 is used, the standard TCP port for the OPC UA binary protocol.
Minimum
supported publishing
interval
Minimum publishing interval supported by the server application at which the
process data is published for logged on OPC UA clients. Lower values set by
an OPC UA client are not taken into account.
Range of values: 10 .. 65535 ms
Default setting: 50 ms
Diagnostic settings
In the "Diagnostic settings" area, you can define which diagnostic information can be called
up via specific channels.
Table 7- 10 Description of the parameters
Parameter
Description
Parallel
In addition to an existing connection, e.g. to a controller (PLC), parallel diag-
nostics access via the OPC UA channel can be enabled. In the case of parallel
access, please note that the OPC UA client only has read access to the com-
munication module.
Diagnostics
Diagnostic information is transmitted to the OPC UA client. The diagnostic
information includes:
•
Information about remote reader commands
•
Information on presence of reader
•
Transmission of log entries
Read point (1-2)
Definition of the read point via which the log entries are transmitted. The dis-
played names depends on the interface names specified in the "Reader inter-
face" menu.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...