Service and maintenance
10.2 Error messages
SIMATIC RF166C
136
Operating Instructions, 12/2019, C79000-G8976-C578-01
"ER"
LED
Block (hex)
Error description
4x
0xE2FE0100 Field disturbance on reader
Possible causes:
•
The reader is receiving interference pulses from the environment.
–
External interference field. The interference field can be detected with the "inductive field
indicator" of the mobile reader.
–
The distance between two readers is too small and does not correspond to the configura-
tion guidelines.
–
The connecting cable to the reader is defective or too long or does not comply with the
specification.
•
Too many transmit errors
The transponder was unable to receive the command or the write data from the communica-
tion module correctly even after several attempts.
–
The transponder is positioned exactly in the limit area of the transmission window.
–
Data transmission to the transponder is being affected by external interference.
•
CRC sending error
–
The transponder reports CRC errors frequently (transponder is positioned in the limit area
of the reader; transponder and/or reader has a hardware defect).
•
Only during initialization: CRC error on receipt of acknowledgment from transponder (cause
as for field interference on the reader).
•
When formatting, the transponder must be in the transmission window of the reader, other-
wise a timeout error will occur, in other words:
–
The transponder is located exactly in the limit range of the transmission window.
–
The transponder is defective and consumes too much power.
–
The EEPROM transponder was incorrectly configured by "FORMAT".
•
RF600:
–
No ETSI channel is available.
–
An incorrect communication standard was selected in the "INIT" command.
–
The expert parameter is incorrect.
–
The performance check of the ETSI radio profile is faulty.
4x
0xE2FE0200 More transponders are located in the transmission window than can be processed at the same
time by the reader.
4x
0xE2FE8100 There is no transponder with the required EPC ID/UID in the transmission window or there is no
transponder at all in the antenna field.
4x
0xE2FE8200 The requested data is not available.
4x
0xE2FE8300 CRC error in reader-transponder communication.
4x
0xE2FE8400 The selected antenna is not enabled.
4x
0xE2FE8500 The selected frequency is not enabled.
4x
0xE2FE8600 The carrier signal is not activated.
4x
0xE2FE8700 There is more than one transponder in the transmission window.
4x
0xE2FE8800 General radio protocol error
--
0xE3FE0100 The file name is not allowed.
--
0xE3FE0200 The file does not exist.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...