Service and maintenance
10.2 Error messages
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
135
"ER"
LED
Block (hex)
Error description
4x
0xE1FE0300 Address error
The address range of the transponder has been exceeded.
Possible causes:
•
Start address of the command start has been incorrectly set.
•
Wrong transponder type
•
The area to be written to is write-protected.
4x
0xE1FE0400 Initialization error
Transponder is unable to execute the initialization command
Possible causes:
•
Transponder is defective.
4x
0xE1FE0500 The transponder memory is full.
4x
0xE1FE0600 Error in transponder memory
The transponder has never been written to or has lost the contents of its memory due to battery
failure.
Possible causes / action to be taken:
•
Replace the transponder (if the battery bit is set).
•
Re-initialize the transponder.
4x
0xE1FE0700 ECC error
4x
0xE1FE0800 The transponder in the antenna field does not have the expected UID / EPC ID or has no UID /
EPC ID.
4x
0xE1FE0900 The command is not supported by the transponder.
4x
0xE1FE0A00 The transponder is read/write-protected.
4x
0xE1FE8100 The transponder is not responding.
4x
0xE1FE8200 The transponder password is incorrect. Access is denied.
4x
0xE1FE8300 The verification of the written transponder data has failed.
Possible causes:
•
Transponder is defective.
•
Transponder is in the limit area.
4x
0xE1FE8400 General transponder error
4x
0xE1FE8500 The transponder has too little power to execute the command.
Possible causes:
•
Transponder is in the limit area.
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...