Programming via OPC UA
9.2 OPC UA variables
SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
115
Diagnostics - Log
These variables supply various log information of the communication module.
Table 9- 22 LastLogEntry
Path
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/Logbook/LastLogEntry
Data type
String
Access
R
Description
Log diagnostics
The last entry in the log is output.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Possible values
Example:
2018-05-30T13:14:43.546+00:00 | COMMANDS | readTagIDs |
CMD | 0 | Readpoint_11 | 000000005575B67D | PC=0000 |
RSSI=0 | Pwr=0
Table 9- 23 LogColumns
Path
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/Logbook/LogColumns
Data type
String
Access
R
Description
Log diagnostics
The headers column of the communication modules log is output
as formatted string. The individual fields are separated by semi-
colons.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Possible values
Date_Time ; Type ; Entry ; Command_Type; Sequence_Number ;
Readpoint ; EPCID_UID ; PC ; RSSI ; Power
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...