Programming via OPC UA
9.2 OPC UA variables
SIMATIC RF166C
108
Operating Instructions, 12/2019, C79000-G8976-C578-01
Table 9- 10 RfPower
Path
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/RfidS
ettings/Antennaxx/RfPower
Data type
SByte
Access
R/W
Description
Radiated power of the antenna
Possible values
0 … 127
The special features of the different reader types are described
below:
With RF380R:
•
2: 0.5 W
•
3: 0.75 W
•
4: 1.0 W
•
5: 1.25 W
•
6: 1.5 W
•
7: 1.75 W
•
8: 2.0 W
Settings outside the specified values mean that the default value
of 1.25 W is used.
For UHF readers:
Radiated power of the antenna in [dB]
•
0
•
5 ... 33
Settings outside of the specified values are set to the respective
area limits (1-4
⇒
5; 34-127
⇒
33).