Programming via OPC UA
9.3 OPC UA events
SIMATIC RF166C
118
Operating Instructions, 12/2019, C79000-G8976-C578-01
Table 9- 26 DeviceName
Data type
String
Description
DisplayName of the read point from which the event comes.
This Property is inherited from "AutoIdDiagnosisEvent". The
BrowseName of the read point is supplied via the standard prop-
erty "SourceName" of "BaseEvent".
Possible values
Example:
Readpoint_11
Table 9- 27 Client
Data type
String
Description
Client interface via which the last transponder access or the last
command on this read point took place.
Possible values
•
PB: Access via PROFIBUS
•
EIP: Access via EtherNet/IP
•
OPCUA: Access via OPC UA
•
WBM: Access via WBM
Table 9- 28 Command
Data type
String
Description
Command that was executed during the last transponder access
operation.
Possible values
Depending on the client interface used:
PROFIBUS (Ident profile):
•
INVENTORY
•
WRITE-ID
•
KILL-TAG
•
LOCK-TAG-BANK
•
PHYSICAL-READ
•
PHYSICAL-WRITE
•
FORMAT
•
TAG-STATUS
•
GET
•
PUT
•
NEXT
PROFIBUS (FB 45):
•
WRITE
•
READ
•
INIT
•
MDS_STATUS
Содержание SIMATIC RF166C
Страница 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 14: ...Security recommendations SIMATIC RF166C 14 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 98: ...Programming via SIMATIC controller SIMATIC RF166C 98 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 156: ...Service and maintenance 10 5 Module replacement SIMATIC RF166C 156 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Страница 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...