Siemens Building Technologies
Fire Safety & Security Products
07.2009
12.13 Engineer Reset Mode
[TM4] By Engineer PIN
NOTE
This menu is only active, if at least one parameter in the beforehand menu “Engineer reset on”
is set!
Local only
When this parameter is selected, the customer has the engineer PIN to reset one of those 3 alarms (Tamper,
burglar and panic).
Local / Remote
When this parameter is selected, the customer doesn’t have the engineer PIN.
In this case the customer has to call up the installer to tell them the three-digit number on the keypad. The
installer will be able to generate a six-digit code (external code generator) to reset the alarm.
Local User can set
(never used, because of
insurance guidelines)
When this parameter is selected, the customer can arm the system without resetting the alarm by engineer
PIN.
Notice, the alarm info will stay at the panel, until somebody is resetting the panel with engineer access. This
parameter will disable the settings “Engineer Reset on”
12.14 ISDN Access type
Choose the right protocol:
z
Point to Point (directly ISDN from a provider)
z
Point to Multipoint (behind a TVA )
12.15 IP Settings (using Sylcom)
12.15.1 IP Address
NOTE
Those settings are only used when the TCP/IP functions of SMN42/43 (IP/GSM Module for Sintony)
are used.
IP parameters are stored only in the PR0 file, they are not downloaded into the control panel.
NOTE
Other settings have to be done, to establish a working IP connection;
z
Set “Up/Download Mode” to Level 1 in the menu System
z
Set the protocol to one of TCP/IP-Protocols in the menu ARC
12.15.2 IP Router
Enter the Sintony IP address router: used in special case with DSL lines and Network Address Translation
(NAT) function.
]
Enter the Sintony IP address, e.g. 143.99.16.120 and use IP Port 1 (08500)