System Input Transmission
[TM66] Transmission lines
Every transmission can be programmed individually per Input and receiver.
49 - 55: PA Keypad
The panic alarm of the individual keypads can be transmitted, depending on the protocol. To do this the
code is determined from the line type for protocols with a fixed code assignment. Otherwise the code or
channel can be chosen as required.
56: System Tamper
Is transmitted on a system tamper alarm. The following are regarded as internal system tamper:
z
Open central control unit or E-bus components
z
Loss of E-bus components
Internal Tamper alarm ( i.e. SAT12).
57: Mains Failure
Is transmitted in the event of a mains fault in the central control unit or one of the external power supply
assemblies. Clear message when fault ends.
58: Bat/Fus Failure
Is transmitted in the event of a battery fault in the central control unit or one of the external power supply
assemblies. Clear message when fault ends.
065: Initialisation
Is transmitted on initialization of the central control unit. No clear message.
066: Auto Test 1
Transmission of test call to Receiver 1. For a transmission to take place, a value other than 000 must be
programmed for the test period in the “ Receiver 1 Telekom Options “ (TM61) in the engineer menu. This
line can also be transmitted to Receiver 2 and to Service 1 and Service 2. In this case, however, the test
period of Receiver 1 applies. Clear message immediately after test call.
067: Auto Test 2
Transmission of test call to Receiver 2. For a transmission to take place a value other than 000 must be
programmed for the test period in the “ Receiver 2 Telekom Options “ (TM62) in the engineer menu. This
line can also be transmitted to Receiver 1 and to Service 1 and Service 2. In this case, however, the test
period of Receiver 2 applies. Clear message immediately after test call transmission.
068: Transmission Test
Transmissions on a test call activation in the “Transmission test” (TM85) engineer menu. Clear message
immediately after the test call transmission.
069: Trouble
Is transmitted in the event of a trouble in the system.
z
Failure Power connection
z
Failure Battery
z
Failure E-Bus
z
Serial Connection
z
Failure Transmission (max. number of calls exceeded)
070: Full Set System
Is transmitted when the complete system (all partitions) is full set if there is only one partition, the system is
considered full set if this one partition is full set. See also "Partitions system options" (TM53) engineer
menu. Clear message when partition unset.
071: Restricted Full Set
Is transmitted when the complete system (all partitions) is full set but at least one input (line) is switched
on. Clear message when the line is again switched off (see "Partitions system options" (TM53) and
"Forced set options" parameters in the engineer menu) or a partition unset.
072: Local programming
Is transmitted when local programming is taking place, e.g. under the following circumstances:
z
Keypad
On access via the keypad, the program is locally transmitted before access to the engineer menu. Clear
message after end of programming.
z
Sylcom
On access with Sylcom, program is not local until after the end of the programming. Clear message imme-
diately after local programming transmission.
073: Remote Program
Transmission depends on the programmed up/download option in the "Other Telekom Options" (TM56) in
the engineer menu.
z
Direct call
Direct call by Sylcom without user authorization. Transmission of remote programming after the end of the
up/download. Clear message immediately after the remote programming transmission.
z
Callback free number without authorization
Callback to any freely selected number without local user authorization. Transmission of the remote pro-
gramming before the start of up/download. Clear message after the end of the up/download.
z
Callback to programmed number without authorization
Callback to programmed number without local user authorization. Transmission of the remote program-
ming before the start of up/download .Clear message after the end of the up/download..
z
Callback to free number with authorization
Callback to free selectable number with local user authorization. Transmission of remote programming
with user authorization before the start of up/download. Clear message after the end of the up/download.
z
Callback to programmed number with authorization
Callback to programmed number with local user authorization. Transmission of remote programming with
user authorization before the start of the up/download. Clear message after the end of the up/download.