Video
64
Siemens Building Technologies
Fire Safety & Security Products
07.2009
11.7 Alarm with local Video
[TM5164] Local Video
This menu function enables the local video to be programmed. The functions of a single video switch and
video on alarm are available. These functions are system functions and independent of partitions. In the case
of local video, the video pictures are displayed locally on a monitor.
In the case of the video switcher, one video picture after the other can be displayed on the monitor. The
changeover takes place in the sequence of the switch position. If the video on alarm function is used, the
corresponding address is bypassed when the corresponding input is triggered on the monitor.
Auto continuance
This parameter acts only on the video and alarm function. If the video on alarm function is used, this function
can be used to determine whether the system automatically continues the switcher after 5 minutes. If this
function is not switched on, the video picture remains a ????
11.8 Alarm on Camera
Video on alarm
Triggered cameras can be switched to the monitor by means of this function. This interrupts the switcher.
The name of the actual address (camera) is shown on the keypad. The switcher can be resumed via the
video keypad. Triggering of a different address switches the monitor to this address. If no one switches the
switcher on again, the monitor remains at the last triggered address. This can be prevented by activating the
"automatic resumption" function (see above).
11.9 Camera
Power
Option
[TM5165] Camera ready This menu function enables the saving of the first video picture to be matched to the readiness state of the
camera. This can be chosen to be between 1 or 3 seconds after the alarm. Fundamentally, it can be said that
all cameras not permanently switched on should be set to 3-second switching. Cameras which are switched
on can be programmed to 1 second. This parameter applies to the complete system.
Содержание SI120
Страница 99: ......