Inputs
25
Siemens Building Technologies
Fire Safety & Security Products
07.2009
6.3.17 Audible Panic Alarm
Audible Panic Alarm
UK, HU, BE
Panic alarm with activation of the bell and strobe light outputs. This input acts, regardless of the setting,
on the panic alarm output. In the case of physical inputs, a direct alarm takes place when the keys of the
remote keypad are pressed and held for at least 2 seconds (refer to remote keypad instructions). The
"Panic Alarm" output is latched until the alarm is rest.
Input triggered
Æ
Panic alarm in the assigned partition.
Partition mode:
Unset
Part set
Full set
Effects on the following outputs when the below partition parameters are preset:
X X X External
bell
X X 2 Internal
bell
X X X Strobe
light
X X Cannot
full
set
X
Cannot part set
X X X Alarm
in
memory
X X X Panic
alarm
5 5 5 Buzzer
X
X
X
Panic alarm system transmission line
X
X
X
Panic alarm partition transmission line
X X X Transmission
line
input
Partition parameters:
X =
Triggering regardless of the partition mode.
2 =
Triggering only if the internal bell “When Full Set” in the partition parameter is chosen.
5 =
Triggering only if “Buzzer On” in the keypad parameter is chosen.
Audible Panic Alarm
All other country versions
Panic alarm with activation of the bell and strobe outputs. This input acts, regardless of the setting, on
the panic alarm output, which on triggering is activated for 10 seconds. In the case of physical inputs, a
direct alarm takes place when the keys on the remote keypad are pressed and held for at least 2 sec-
onds (refer to remote keypad instructions).
Input triggered
Æ
Panic alarm in the assigned partition.
Partition mode:
Unset
Part set
Full set
Effects on the following outputs when the below partition parameters are preset:
X X X External
bell
X X 2 Internal
bell
X X X Strobe
light
X X Cannot
full
set
X
Cannot part set
X X X Alarm
in
memory
X X X Panic
alarm
(10
seconds)
X
X
Block lock not released
5 5 5 Buzzer
X
X
X
Panic alarm system transmission line (10 seconds)
X
X
X
Panic alarm partition transmission line (10 seconds)
X
X
X
Transmission line input (10 seconds)
Partition parameters:
X =
Triggering regardless of the partition mode.
2 =
Triggering only if internal bell parameter “When Part Set” is chosen.
5 =
Triggering only if “Buzzer On” in the keypad parameter is chosen.