Service
79
Siemens Building Technologies
Fire Safety & Security Products
07.2009
14.2.2 Protocol (Service 2)
Protocol for Service 2
Either Sylcom or one of the integrated pager protocols can be selected here.
Pager protocol
With the pagers, the Service 2 site number (8-digit) followed by an alarm code (1-digit) is transmitted.
Pager alarm code
The alarm codes mean the following alarm types:
z
Code 1
Æ
Panic alarm
z
Code 2
Æ
Burglar alarm
z
Code 3
Æ
Panic alarm
z
Code 4
Æ
Voltage alarm
z
Code 5
Æ
Voltage alarm
z
Code 8
Æ
Other alarms
Log book to Sylcom
Pager TAMTAM
Pager TATOO
Pager
Pager KOBBY
Siren
*GSM SMS
SMS Header: Home panel
14.2.3 GSM
GSM SMS protocol
If this protocol is selected, the user is able to set 16 characters for the GSM header.
IP/GSM(GPRS) Module SMN 43 – sending SMS
z
In combination with the IP/GSM(GPRS) module (SMN 43) Sintony can send a
SMS message, independent from the alarm transmission. Therefore the func-
tionality “Transmit message to Service 2” is used.
z
If this option is chosen in the control panels in combination with a “Serial port“
set to SMN42 (ARC1 parameter), then the according message is generated from
Sintony and the SMN43 sends a SMS to the phone number.
z
In the “Inputs transmission” and “System Input Transmission” definition the engi-
neer has to choose the message to send.