Outputs
51
Siemens Building Technologies
Fire Safety & Security Products
07.2009
8.2.41 RF Control 1 – 2
RF Button 1
This output is triggered via key
“
1”
on the radio remote control. Triggering can take place either as a "static"
or "dynamic" triggering for a programmable activation time (127 seconds/minutes).
RF Button 2
This output is triggered via key “
2”
on the radio remote control. Function as for radio key “
1”
.
8.2.42 Duress
PIN
Duress PIN
This output is activated if a duress PIN is entered at a remote keypad [TM21].
8.2.43 PIN
Tamper
PIN Tamper
This output is activated if a PIN is incorrectly entered four times at a remote keypad.
8.2.44 Battery Supervision (SI120 only)
Battery / Fuse Failure
Output logical type “Battery supervision” is a pulse output used with SMX23/SMX26 to trigger battery test.
This output is switched on if there is a power supply or fuse failure (Sytem Input) and switched off if the
problem has disappeared again.
8.2.45 Burglar Tamper alarm
Burglar or Tamper alarm
This output is activated if Burglar or Tamper alarm occurs.
8.2.46 Valid
PIN
Valid PIN
This output is activated if the valid PIN is entered.
8.2.47 Input
Follower
Input Follower
Either the output follows the “
Physical State Only”
of the selected Input or it follows the “
Ph Logical
State”
of this Input.
z
Physical and Logical State:
The output is triggered by the selected physical state. Depending on the input type (defined for the selected
input) the control panel has an internal logical state. The output is put in the quiescent state, when the logical
state is inactive.
z
Physical State Only:
The output follows the physical state of selected input. With this setting the real output state (on/of) of a
connected detector is processed.
z
True/NO an False/NC will invert the output
Example:
An input is of type BA. If a detector triggers the alarm input, the control panel generates a logical alarm mes-
sage “Begin Alarm” which is also stored in the log book. The logical input remains still active, even if the
detector alarm is not anymore present. The “End Alarm” is generated, when the alarm memory is reset (e.g.
by the user).
If the “Activation Time” parameter of this output is set to 000, the output will follow exactly the Input.
If the “Activation Time” parameter of this output is different to 000, the output will remain active during the
corresponding time (max. 127 minutes or seconds) even if the input is back to a quiet state, but will be not
re-trigger if the input is active longer than the “Activation Time” delay.
This output type functionalities is independent of the set/unset/part-set State of the Control Panel.
8.2.48 Line Off Hook
Line off Hook
This Output is triggered by incoming Call