Inputs
24
Siemens Building Technologies
Fire Safety & Security Products
07.2009
6.3.16 Silent Panic Alarm
Silent Panic
Alarm
UK, HU, BE
A silent panic alarm is triggered, e.g. neither the outputs for strobe lights nor those for the bells are activated. This input acts
on the panic alarm output regardless of the set state. In the case of physical inputs, a direct alarm takes place when the keys
on the remote keypads are pressed and held for at least 2 seconds (refer to remote keypad instructions).
The output "Panic Alarm" remains stored until alarm is reset.
The "Alarm in Memory" and "Cannot Set” remote keypad LEDs are not activated until a PIN for the corresponding partition is
input.
Input triggered
Æ
Silent panic alarm in assigned partition.
Partition mode:
Unset
Part
set
Full set
Effects on the following outputs when the below partition parameters are preset:
X
X
Cannot full set
X
Cannot part set
X
X
X
Alarm in memory
X X
X
Panic
alarm
X
X
X
Panic alarm system transmission line
X
X
X
Panic alarm partition transmission line
X
X
X
Transmission line input
X =
Triggering regardless of the partition mode.
Silent Panic
Alarm
All other
country
versions
Silent panic alarm is triggered, e.g. neither the outputs for strobe lights nor those for the bells are activated. This input acts
on the panic alarm output, which is activated for 10 seconds on a triggering, regardless of the set state. In the case of physi-
cal inputs, a direct alarm takes place when the keys on the remote keypads are pressed and held for at least 2 seconds
(refer to remote keypad instructions).
Input triggered
Æ
Silent panic alarm in assigned partition.
Partition mode:
Unset
Part set
Full set
Effects on the following outputs when the below partition parameters are preset:
X
X
Cannot full set
X
Cannot part set
X
X
X
Alarm in memory
X
X
X
Panic alarm output (10 seconds)
X
X
Block lock output not enabled
X
X
X
Panic alarm system transmission line (10 seconds)
X
X
X
Panic alarm partition transmission line (10 seconds)
X
X
X
Transmission line input (10 seconds)
X =
Triggering regardless of the partition mode.