7ML19981BC01
5
InterRanger
DPS300
SPECIFICATIONS
Electronics
Power:
!
100/115/200/230 V AC
±
15%, 50/60 Hz, 31 VA
Environmental:
!
location
!
indoor / outdoor
!
altitude
!
2000 m max
!
ambient temperature
!
-20 to 50°C (-5 to 122 °F)
!
relative humidity
!
suitable for outdoor (Type 4X /
NEMA 4X / IP65 enclosure)
!
installation category
!
II
!
pollution degree:
!
4
Scan Points:
!
2 points per DPS300
Accuracy:
!
1% of program range* or 2 cm (0.8”), whichever is greater
(ideal conditions)
Resolution:
!
1% of program range* or 2 cm (0.8”),
whichever is greater (ideal
conditions)
Memory:
!
EEPROM (non-volatile) no back-up battery required
Programming:
!
via removable programmer and / or Dolphin Plus interface package
Display:
!
custom graphics, backlit LCD with 51 x 127 mm (5 x 2”) viewing
area
Temperature :
!
-50 to 150 °C (-58 to 302 °F)
Compensation
!
integral transducer sensor
!
2 TS-3 temperature sensors, max.
!
programmable fixed temperature
Temperature Error:
!
with compensation:
!
0.1% of range
!
fixed temperature:
!
0.22% / °C deviation from
programmed temperature.
Outputs:
!
transducer drive:
!
150 to 315 V peak
!
relays:
!
4 alarm/control relays
!
1 form “C” SPDT contact per relay,
!
rated 5 A at 250 V AC, non-inductive
!
mA output:
!
2 outputs max.
!
0.1% resolution
!
0-20 or 4-20 mA, scalable
!
750
Ω
, isolated, 30 V rms
*
program range
is defined as the empty distance to the face of the transducer
(P006) plus any range extension (P801).