Service Instructions NFF
Stromag Dessau
IP 66
safety in motion
Electromagnetic Double Face Spring – Applied Brake
01.06.2009
14
8 Maintenance
8.1
Maintenance and inspection work
Make sure to comply with Chapter 2 "Safety guidelines" during all maintenance and
inspection work.
As the brakes work under varying operating conditions, it is not possible to pre-define wear
check, inspection, maintenance and repair intervals.
Higher loads on the brake (e.g. as a result of torque, speed, switching frequency, ambient
temperature etc.) require shorter maintenance intervals.
Therefore it is first of all necessary to observe the brake with regard to safety and wear, and
then adapt the maintenance intervals in accordance with the observations made.
Wear of the friction lining will result in a greater air gap „off“.
Depending on the load on the brake, the air gap must be checked from time to time. This will be
done by measuring the air gap according to chapter 8.2.
If the max. air gap as determined in chap. 1.1. is reached please readjust the air gap described
in chap.8.3.
Caution!
If wear re-adjustment is not carried out early enough, both the transmission of the rated load
torque and the lifting of the brake will not be ensured.
8.2
Measurement of the air gap
The measurement of the air gap between coil body (1) and armature disc (10) can only be done
when the coil is currentless.
The measurement of the air gap must be taken on two places be opposited 180°. Therefore
remove the two cap screws (65) in the outer body and control with a finger gauge. The air gap
between the armature disc (10) and coil body (1) must be between „off min.“ and „off max.“
described in chap.1.1.
After the measurement the thread hole must be closed with cap screw (65) and sealing ring for
protection of IP 66.
8.3 Wear
re-adjustment
When the maximum ‘air gap off’ has been reached in brakes (chap.1.1) a onetime wear re-
adjustment is possible.
Important! Check up: the brake must be torque-free on the output side.
Disconnect the brake from current.
Proceed as follows (fig. 1)
155
Содержание 1PH818
Страница 2: ...18 07 2016 14 04 V14 00 ...
Страница 12: ...Introduction SIMOTICS M 1PH8 1PH818 1PH822 12 Operating Instructions 07 2016 ...
Страница 28: ...Description SIMOTICS M 1PH8 1PH818 1PH822 28 Operating Instructions 07 2016 ...
Страница 48: ...Preparations for use 4 14 Converter operation SIMOTICS M 1PH8 1PH818 1PH822 48 Operating Instructions 07 2016 ...
Страница 82: ...Electrical connection 6 4 Auxiliary circuits SIMOTICS M 1PH8 1PH818 1PH822 82 Operating Instructions 07 2016 ...
Страница 100: ...Operation 8 10 Faults SIMOTICS M 1PH8 1PH818 1PH822 100 Operating Instructions 07 2016 ...
Страница 126: ...Spare parts 10 9 Speed encoder type 1PH818 1PH822 SIMOTICS M 1PH8 1PH818 1PH822 126 Operating Instructions 07 2016 ...
Страница 136: ...Quality documents SIMOTICS M 1PH8 1PH818 1PH822 136 Operating Instructions 07 2016 ...
Страница 163: ...D 3 Operating instructions of the EC external fan SIMOTICS M 1PH8 1PH818 1PH822 Operating Instructions 07 2016 163 ...
Страница 197: ...AA Manual STROMAG Break AC Manual Ziehl Abegg external fan ...
Страница 198: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...