1XB7 700
1XB7 712 (*)
①
main terminal
③
signal connection terminal
②
ground terminal
④
signal connection
Table 6-2
Data for electrical connection
Terminal box type
1XB7 322
1XB7 422
1XB7 700
1XB7 712 (*)
Cable entry
2 x M50 x 1.5
2 x M63 x 1.5
3 x M75 x 1.5
4 x M75 x 1.5
Max. poss. cable outer diameter
38 mm
53 mm
68 mm
68 mm
Number of main terminals
3 x M12
3 x M12
3 x 3 x M12
3 x 4 x M16
Max. cross-section per terminal
2 x 50 mm
2
2 x 70 mm
2
3 x 150 mm
2
4 x 185 mm
2
Max. current per terminal
①
210 A
270 A
700 A
1150 A
Number of ground terminals
4 x M6
4 x M8
Terminal strip
4 x M16
①
Current carrying capacity based on IEC / EN 60204-1 or IEC / EN 60364-5-32
6.3.5
Connection with cable lugs
1. To connect the cables to the main terminals, select cable lugs that match the necessary
cable cross-section and appropriate screw size.
The connectable cable cross section is determined by the cable lug size for example.
– Cable lug in accordance with DIN 46234 from 35 mm
2
to 185 mm
2
,
– Cable lug in accordance with DIN 46235 from 35 mm
2
to 185 mm
2
.
Observe the possible outer diameter of the connecting cable in the chapter entitled
"Electrical connection data".
Connect only one conductor per cable lug.
2. Remove the insulation from the conductor ends so that the remaining insulation is almost
long enough to reach the cable lug.
Electrical connection
6.3 Connecting
SIMOTICS M-1PH8 1PH818., 1PH822.
Operating Instructions 07/2016
71
Содержание 1PH818
Страница 2: ...18 07 2016 14 04 V14 00 ...
Страница 12: ...Introduction SIMOTICS M 1PH8 1PH818 1PH822 12 Operating Instructions 07 2016 ...
Страница 28: ...Description SIMOTICS M 1PH8 1PH818 1PH822 28 Operating Instructions 07 2016 ...
Страница 48: ...Preparations for use 4 14 Converter operation SIMOTICS M 1PH8 1PH818 1PH822 48 Operating Instructions 07 2016 ...
Страница 82: ...Electrical connection 6 4 Auxiliary circuits SIMOTICS M 1PH8 1PH818 1PH822 82 Operating Instructions 07 2016 ...
Страница 100: ...Operation 8 10 Faults SIMOTICS M 1PH8 1PH818 1PH822 100 Operating Instructions 07 2016 ...
Страница 126: ...Spare parts 10 9 Speed encoder type 1PH818 1PH822 SIMOTICS M 1PH8 1PH818 1PH822 126 Operating Instructions 07 2016 ...
Страница 136: ...Quality documents SIMOTICS M 1PH8 1PH818 1PH822 136 Operating Instructions 07 2016 ...
Страница 163: ...D 3 Operating instructions of the EC external fan SIMOTICS M 1PH8 1PH818 1PH822 Operating Instructions 07 2016 163 ...
Страница 197: ...AA Manual STROMAG Break AC Manual Ziehl Abegg external fan ...
Страница 198: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...