Rel. Adr.
Description
1.0
•
Bit = 1: Switch off laser
•
Bit = 0: Switch on laser
Type
•
1 bit
1.1 ... 1.7
Reserved
Type
•
1 bit
10.3.9
Module 13:
Temp/i1b, Level/i2b, Hrs/i2b
Type
Input module, 5 bytes, consistent
Description
The diagnostic data of the device can be read using this module.
Input values
Rel. Adr.
Description
0
Device temperature [°C]
Type
•
Signed 8-bit number in two´s complement
1
Signal attenuation [dB]
see "Received signal level", page 28
Type
•
Signed 16-bit number in two´s complement
3
Operating hours in units of 10 hours.
Type
•
Signed 16-bit number in two´s complement
10.3.10
Module 20:
Setup MFx
Type
Configuration module, no input and output data
Description
This module defines the behavior of the switchable MF1 input and output.
Table 32: Module parameters for
Setup MFx
Name
Description
MFx
Activate or deactivate MF1 and MF2.
Options
•
enable
•
Disable
Factory setting
•
enable
PROFIBUS INTERFACE
10
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
69