Parameter
Description
ErrRej
Select time for maximum error suppression. If no measurement is possible
due to an error (e.g. brief light beam interruption), measured value are
extrapolated until no later than when the set error suppression time expires.
During this time, a
WrnPlb
plausibility warning is output. If no measurement
is possible after expiration of the error suppression time, measured value
0, plausibility error
ErrPlb
and possibly other errors (e.g. level error
ErrLvl
) are
output.
Options
•
200 ms: Plausibility error is reported when the error is indicated for
longer than 200 ms.
•
50 ms: Plausibility error is reported when the error is indicated for longer
than 50 ms.
•
Off: The plausibility error is reported when the error is indicated for
longer than 5 ms.
Factory setting
•
200 [ms]
Heat
NOTE
Only for DL100-xxHxxxxx variants with heating
In this menu, you can set the ambient temperature at which the heating
turns on if undercut. The hysteresis is fixed at 3 K. Increasing the tempera‐
ture set at the factory can reduce the formation of condensation in some
cases.
Options
•
–10 … +40 °C
Factory setting
•
–10 °C
FrqSet
NOTE
Only for DL100-xxxBxxxx variants with frequency changeover
You can set laser transmission frequencies in this menu. If the minimum
distance between the optical axes cannot be maintained when mounting
several distance sensors, mutual interference is prevented by setting differ‐
ent frequencies (mode 0 ... mode 2). No minimum distance is required for
this purpose
see "Placement of multiple distance sensors", page 21
.
Mode 0 corresponds to the laser transmission frequency of the variant
without switchable frequency (DL100-xxxAxxxx). Mode 3 is reserved for later
use.
Options
•
Mode 0
•
Mode 1
•
Mode 2
•
Mode 3 (reserved)
Factory setting
•
Mode 0
Reset
Reset to factory settings
see "Performing a reset", page 46
7.1.17
Performing a reset
1.
Select the
Reset
parameter in the
SpecFu
menu
2.
Press the
pushbutton.
✓
The
Sure?
confirmation prompt appears.
3.
Press the
pushbutton to terminate the process.
7
OPERATION
46
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
8014755/19H8/2021-10-15 | SICK