Table 33:
MF1
module parameter
Name
Description
Function MF1
Select function for MF1 input and output.
Options
•
[Output] Distance Threshold
: Output is switched when the distance has
been overwritten from the module parameter
[MF1 Distance] threshold
.
•
[Output] Speed Threshold
: Output switches when the speed limit from
the
[MF1 Speed] Threshold
module parameter has been exceeded. The
direction is set in the
[MF1 Speed] Mode
module parameter.
•
[Output] Service
: The output switches if at least one of the service bits
selected under
[MF1 Service] Laser Warning...[MF1 Service] Heating
has
been set.
•
[Input] Laser Off
: Measurement laser is deactivated via the input.
•
[Input] Preset Static
: "Preset Static” function activated via the input.
Factory setting
•
[Output] Distance Threshold
[MF1] Active State
Select active level or signal edge of MF1
Options
•
low
•
High
Factory setting
•
low
[MF1 Distance] Thresh‐
old [mm]
Enter the distance threshold value.
Options
•
-300,000 ... 300,000 [mm]
Factory setting
•
1,990 [mm]
[MF1 Distance] Hyste‐
resis [mm]
Enter the distance threshold hysteresis
Options
•
1 ... 300,000 [mm]
Factory setting
•
10 [mm]
[MF1 Speed] Threshold
[mm/s]
Enter speed threshold. The switching hysteresis is fixed at 100 mm/s.
Options
•
0 ... 15,000 [mm/s]
Factory setting
•
5,000 [mm/s]
[MF1 Speed] Mode
Select direction for detecting the speed overrun.
Options
•
negative direction [-]
•
positive direction [+]
•
both directions [+/-]
Factory setting
•
both directions [+/-]
10
PROFIBUS INTERFACE
70
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
8014755/19H8/2021-10-15 | SICK
Subject to change without notice