Temp/i1b: Input value to the master consisting of 1 byte with the
Temp
(tempera‐
ture) designation
•
Level/i2b: Input value to the master consisting of 2 bytes with the
Level
designa‐
tion
•
Hrs/i2b: Input values to the master consisting of 2 bytes with the
Hrs
(operating
hour counter) designation
Definitions
•
A byte is an 8-bit value.
•
A word is a 16-bit value.
•
Consistency means that all values within a module are updated simultaneously.
•
An input value is transmitted cyclically from the device to the master (PLC).
•
An output value is transmitted cyclically from the master (PLC) to the device.
•
A configuration value is transferred from the master to the device every time the
device is connected. For example, when switching on the PROFIBUS device or the
master or after the connection has been interrupted.
Relative address specification
For input and/or output modules, the relative addresses of the input or output values
are specified in the module descriptions
see "Module description", page 59
in one of
the following formats:
•
<byte>, e.g., Rel. Addr. 0: byte 0
•
<byte>.<bit position within the entry> e.g., Rel. Addr. 0.31: byte 0, bit 31
•
<byte>. <start bit position ... end bit position within an entry>, e.g., Rel. Addr.
0.0...0.29: byte 0, bit 0...29
10.2.2
Module overview
measured values module overview
Table 28: measured values module overview
Module number
Total size
Module type
Contents
Designation
Type
Size
1
2 words
Input module
Distance
Input
2 words
2
1 word
Input module
Distance
Input
1 word
3
2 words
Input module
Speed
Input
2 words
4
4 words
Input module
Distance
Input
2 words
Speed
Input
2 words
5
2 words
Input and out‐
put module
Distance
Input
2 words
Preset Dyn.
Output
Bit 0 ... 29
Delete Preset
Output
Bit 30
Activate Preset
Output
Bit 31
6
6 words
Input module
Time stamp
Input
4 words
Distance
Input
2 words
7
8 words
Input module
Time stamp
Input
4 words
Distance
Input
2 words
Speed
Input
2 words
10
PROFIBUS INTERFACE
56
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
8014755/19H8/2021-10-15 | SICK
Subject to change without notice