Name
Description
Frequency Mode
NOTE
Only for DL100-xxxBxxxx variants with frequency changeover
Set the laser transmission frequencies. If the minimum distance between
the optical axes cannot be maintained when mounting several distance
sensors, mutual interference is prevented by setting different frequencies
(mode 0 ... mode 2). No minimum distance is required for this purpose
see "Placement of multiple distance sensors", page 21
Mode 0 corresponds to the laser transmission frequency of the variant
without switchable frequency (DL100-xxxAxxxx). Mode 3 is reserved for
later use.
Options
•
Mode 0
•
Mode 1
•
Mode 2
•
Mode 3 (reserved)
Factory setting
•
Mode 0
10.3.14
Module 26:
Setup Free Dist
.
Resolution
Type
Configuration module, no input and output data
Description
This module is used to define the resolution of the distance value when using
free
Distance Resolution
.
NOTE
The settings in this module affect modules 1, 2, 4, 5, 6 and 7 if
free Distance Resolution
has been selected in these modules.
Module parameters
Name
Description
free Distance Resolu‐
tion [μm]
Determines the resolution of the distance value for modules in which
free
Distance Resolution
has been selected.
Options
•
1 ... 100,000 [μm]
Factory setting
•
100 [μm]
10.3.15
Module 27:
Setup Free Speed Resolution
Type
Configuration module, no input and output data
Description
This module is used to set the resolution of the speed value when using
free Speed
Resolution
.
10
PROFIBUS INTERFACE
76
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
8014755/19H8/2021-10-15 | SICK
Subject to change without notice