Module parameters
Name
Description
Distance Resolution
Select the resolution for the distance output value via the digital data
interface. The output value corresponds to the measured value [mm]
divided by the selected resolution. The parameter does not have any
influence on the measured value shown on the display.
If
free Distance Resolution
is selected, the associated value can be set in
module 26
Free Distance Resolution
.
Options
•
0.1 mm
•
0.125 mm
•
1 mm
•
10 mm
•
100 mm
•
free Distance Resolution
Factory setting
•
0.1 mm
Speed Resolution
Select the resolution in mm/s for the speed output value via the digital
data interface. The output value corresponds to the measured value
[mm/s] divided by the selected resolution. The parameter does not have
any influence on the measured value shown on the display.
It is also possible to enter a free resolution. When this is selected, the
associated value can be set in module 27
Free Speed Resolution
.
Options
•
0.1 mm/s
•
1 mm/s
•
10 mm/s
•
100 mm/s
•
free Speed Resolution
Factory setting
•
1 mm/s
10.3.5
Module 5:
Distance/i2w, Preset Dyn./o2w
Type
Input and output module, 2 words, consistent
Description
This module reads the current distance value. When writing the module, the reference
value (preset value) defined in it is transferred to the device. The time the reference
value is applied in the device is determined by setting the most significant bit (0->1
edge change bit 31). The distance value measured at this time is automatically
provided with an offset and therefore adjusted to the reference value. The following
applies: Offset = Preset – measured distance value. Setting bit 30 (0
→
1 edge change)
resets the reference value and offset to
0 mm
.
As an alternative to module 5, a preset can be performed via the digital input MF1,
"Preset – moving to initialization position", page 79
.
NOTE
A reference or offset value changed by this module is always stored in the device. Since
all changed and unchanged parameters are written in the flash memory, the output of
measured values is only available for a short time.
If bit 30 is set, the setting of bit 31 is ignored.