Table 14:
More?
menu
Options
Description
Yes
/
No
Activate or deactivate advanced menu view The entire menu is displayed
when activated. When deactivated, all parameters in
Menu
are hidden
except for the PROFIBUS address
BusAdr
.
Options
•
Yes
•
No
Factory setting
•
No
7.1.7
MFx On menu
In this menu, you can activate or deactivate multifunctional input/output MF1 and
multifunctional output MF2.
Requirement for display
More?
menu:
Yes
option.
Table 15:
MFx On
menu
Options
Description
Enable
/
Disable
Activate or deactivate MF1 and MF2.
Options
•
Enable
: MF1 and MF2 are activated in the hardware.
•
Disable
: MF1 and MF2 are deactivated in the hardware and are therefore
hidden in the menu.
Factory setting
•
Enable
7.1.8
MF1 menu
You can parameterize multifunctional input/output MF1 using this menu.
Requirement for display:
•
more?
menu:
Yes
option
•
Menu
MFx On
:
Enable
option
Table 16:
MF1
menu
Parameter
Description
ActSta
Select the active level or signal edge of the MF1.
Options
•
ActLow
: LOW level output with active output (safety criterion fulfilled) or
activation of input at falling signal edge
•
ActHi
: HIGH level output with active output (safety criterion fulfilled) or
activation of input at rising signal edge
Factory setting
•
ActLow
7
OPERATION
38
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
8014755/19H8/2021-10-15 | SICK
Subject to change without notice