S
et
Es
c
<
<
ca. 1° … 3°
1
2
3
4
Figure 7: Reflector tilt for shiny surfaces and vertical stroke axis
1
Sensor
2
Shiny surface such as a masted automated storage and retrieval system
3
Reflector
4
Tilt of approx. 1° to 3°
5.4
Placement of multiple distance sensors
To mount several distance sensors side-by-side, you will need to maintain a minimum
distance when mounting. The minimum distance
a
of the optical axis depends on the
maximum travel distance s
max
. This applies to mounting with light beams in both the
same and opposite directions.
MOUNTING
5
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
21
Subject to change without notice