Rel. Adr.
Description
0.4
Bit = 1: Plausibility error
No valid measured value can be calculated.
Type
•
1 bit
0.5
Bit = 1: Temperature error
The device is operating outside the specified temperature range.
Type
•
1 bit
0.6
Bit = 1: Signal level error
The signal attenuation is too high.
Type
•
1 bit
0.7
Bit = 1: Laser error
Laser error – the laser diode may have reached the end of its service life
see "Module 13: Temp/i1b, Level/i2b, Hrs/i2b", page 69
.
Type
•
1 bit
1.0
Bit = 1: Laser switched off
Type
•
1 bit
1.1
Bit = 1: Device-internal heating in operation
Type
•
1 bit
1.2
Bit = 1: Either a input level is active at MF1 of the output is active.
Type
•
1 bit
1.3
Bit = 1: MF2 output is active.
Type
•
1 bit
1.4 ... 1.6
Reserved
Type
•
1 bit
1.7
•
Bit = 0: Device ready for operation
•
Bit = 1: Device not ready for operation. Possible causes could be
hardware errors, temperature errors, optical or electrical interference
or a deactivated laser diode.
Type
•
1 bit
Output values
Rel. Adr.
Description
0.0 ... 0.7
Reserved
Type
•
1 bit
10
PROFIBUS INTERFACE
68
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
8014755/19H8/2021-10-15 | SICK
Subject to change without notice