7.1.14
MF2 menu
You can parameterize MF2 in this menu and its submenus.
Requirement for display:
•
more?
menu:
Yes
option
•
Menu
MFx On
:
Enable
option
Table 21:
MF2
menu
Parameter
Description
ActSta
Select active MF2 level.
Options
•
ActLow
: LOW level output with active output (safety criterion fulfilled)
•
ActHi
: HIGH level output with active output (safety criterion fulfilled)
Factory setting
•
ActLow
Functn
Select MF2 function.
Options
•
Dist
: MF2 is used as a distance switch output.
•
Speed
: MF2 is used as a speed switch output.
•
Srvice
: MF2 is used as a service output.
Factory setting
•
Srvice
Count
Counts the switching events of the MF2. You can reset the counter by
switching the device off and on again.
MF2 – Dist
submenu
This submenu corresponds to the
Dist
submenu in the
MF1
menu
MF2 – Speed
submenu
This submenu corresponds to the
Speed
submenu in the
MF1
MF2 – Srvice
submenu
This submenu corresponds to the
Srvice
submenu in the
MF1
menu
7.1.15
Offset menu
You can set an offset in this menu.
Requirement for display:
•
more?
menu:
Yes
option
7
OPERATION
44
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
8014755/19H8/2021-10-15 | SICK
Subject to change without notice