Table 17:
MF1 – Dist
submenu
Parameter
Description
Limit
Set switching threshold for the distance value. The digital output is activated
when the current distance value exceeds the set switching threshold.
Options
•
–300,000 … + 300,000 [mm]
Factory setting
•
1,990 [mm]
NOTE
Because the display can only handle six digits, only negative values down to
–99999
can be input via the operating buttons.
Via SOPAS ET or an existing fieldbus interface, the entire value range is
available as input. For values smaller than
–99999
, the highest decimal
place is truncated in the display.
inactive
active
Limit
Hyst
Dist.
Figure 22: Representation of the
Dist
function
Limit
Distance-based switching threshold
Hyst
Hysteresis of switching threshold
Dist
Measured distance
Hyst
Sets hysteresis for the switching threshold.
Options
•
1… +300,000 [mm]
Factory setting
•
10 [mm]
7.1.10
MF1 – Speed submenu
In this submenu, you can parameterize the MF1 as a speed switching output.
Requirement for display:
•
more?
menu:
Yes
option
•
Menu
MFx On
:
Enable
option
•
Functn
parameter:
Speed
option
7
OPERATION
40
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
8014755/19H8/2021-10-15 | SICK