Table 19:
MF1 – Srvice
submenu
Parameter
Description
WrnLsr
Activates MF1 when the aging of the laser diode means that the device is
nearly due to be replaced.
Options
•
On
•
Off
Factory setting
•
On
WrnLvl
Activates MF1 when the signal attenuation value reaches the critical value,
for example due to contamination.
Options
•
On
•
Off
Factory setting
•
On
WrnTemp
Activates MF1 if the interior device temperature reaches the critical value.
Options
•
On
•
Off
Factory setting
•
On
WrnPlb
Activates MF1 if extrapolated measured values are to be output for implausi‐
ble measured values
,
ErrRej
. This may be caused
by an internal error, hardware errors, obstruction of the light beam, optical
interference or electrical interference.
Options
•
On
•
Off
Factory setting
•
On
NotRdy
Activates MF1 if the device is not ready for operation. Possible causes could
be hardware errors, optical or electrical interference or a deactivated laser
diode. This warning message is also issued during initialization.
Options
•
On
•
Off
Factory setting
•
On
Heat
Activates MF1 if the interior device heating is in operation. This parameter is
only displayed on measuring devices with the “Heating” option.
Options
•
On
•
Off
Factory setting
•
Off
7.1.12
MF1 – LsrOff submenu
You can parameterize the MF1 as a switching input to switch off the laser diode by
selecting
LsrOff
. If MF1 is active, the laser diode is switched off.