NOTE
The settings in this module affect modules 3, 4 and 7 if
free Speed Resolution
has been
selected in these modules.
Module parameters
Name
Description
free Speed Resolution
[μm/s]
Determines the resolution of the speed value for modules in which
free
Speed Resolution
has been selected.
Options
•
1 ... 100,000 [μm/s]
Factory setting
•
1,000 [μm/s]
10.3.16
Module 30:
Serial No/i8b
Type
Input module, 8 bytes
Description
The serial number of the device can be queried using this module.
Input values
Rel. Adr.
Description
0
Displays the serial number as a string in the format
YYWWnnnn
.
•
YY
: Year of manufacture
•
WW
: Week of manufacture
•
nn
: Sequential number
Type
•
8 ASCII characters
10.3.17
Module 31:
Product Code/i9w
Type
Input module, 18 bytes
Description
The product code of the device can be queried using this module.
Input values
Rel. Adr.
Description
0
Displays the product code as a string in the format
DL100-XXXXXXXX
.
Unused characters at the end of the string are filled with 0 bytes (0x00).
Type
•
18 ASCII characters
10.3.18
Module 32:
Version HW/i8b
Type
Input module, 8 bytes
PROFIBUS INTERFACE
10
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
77