41
Spill Containment Separate/Reassemble
Turn the 3way fuel valve lever to the “A” side.
Remove the wiring connector.
Remove the fuel hoses (supply and return sides).
Remove the four spill containment fixing bolts (M12, 4 pieces).
< Note >
When removing the fuel hoses, hold the union joint fixed using a spanner or similar tool.
Prepare a container to receive the fuel remaining in the fuel piping that will flow out of the removed
fuel piping.
Lift the generator, separate the spill containment and set the generator on a flat surface.
After cleaning and inspecting the inside of the spill containment, reassemble the spill
container with this generator by performing the above procedures in the reverse order.
Reassemble the fuel piping and wiring connector to
their original positions.
Turn the 3way fuel valve lever to the “B” side.
< Note >
After reassembling, bleed air from the fuel system.
(Refer to section “9-3. Procedures during Operation”.)
After reassembling, check that there is no fuel leakage.
Spill Containment Cleaning/Inspection
Use a high-pressure cleaner or similar equipment to clean the inside of the spill
containment.
Remove the drain plug (R1”) to drain the cleaning water.
Check that there no rust has developed inside of the spill containment. If rust has
developed, remove the rust and clean again.
Tentatively, apply sealant coating to the plug (R1”) or wrap it in seal tape and reinsert it.
Allow water to accumulate and check that the spill containment has no internal leakage.
Remove the drain plug (R1”) to drain the water.
After the procedures have been completed, apply sealant coating to the plug (R1”) or
wrap it in seal tape and reinsert it.
< Note >
If the fluid drained when cleaning the spill containment contains oil or
grease, dispose of it according to the related laws and regulations.
If the spill containment has a leak, contact the authorized distributor
where the generator was purchased.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
Position B
Position B
Position A
Position A
Drain Plug(R1”)
Содержание DGK20FS
Страница 2: ......
Страница 12: ...9 4 2 Operation Panel Configuration Circuit Breaker Controller Voltage Regulator Power Switch 1 4 3 2...
Страница 51: ...48 13 Circuit Diagram...
Страница 52: ...2022 2021...