33
< Note >
If using a hose for the piping, use oil-
resistant hose with an internal diameter
of 0.31 to 0.35 in (8 to 9 mm).
Set the fuel level of the external fuel
tank from 0 to 10 ft. (3 m) above from
the bottom of this generator. The fuel
level of the external fuel tank being
lower than this generator will result in
poor engine operation or shut off.
Turn the 3way fuel valve lever to the
“B” side in order to prevent fuel from
flowing out from the external tank fuel
inlet/return.
Turn the lever completely. If the lever is not completely pressed to either side, it might not be
possible to supply fuel causing the engine to stop.
Set the supply side so that it is 0.6 to 0.8 in. (15 to 20 mm) above the bottom of the tank in order
to prevent foreign material or water from being suctioned from inside the external fuel tank.
Set the external fuel tank return side at the same height as the supply side in order to
prevent poor engine operation due to air mixed in with the fuel.
Refer to section “
9-2 Procedures during Operation
” for air bleeding.
Air may remain in hoses or pipes immediately after connecting the external fuel tank
resulting in unstable engine speed and engine shut off.
Do not leave the generator unattended for unmanned operation until you have confirmed that
the engine speed is stable.
California Proposition 65
WARNING
Batteries, battery posts, terminals and related accessories contain lead and lead
compounds, and other chemicals known to the State of California to cause cancer
and birth defects or other reproductive harm. WASH HANDS AFTER HANDLING.
WARNING : ELECTRIC SHOCK / INJURY
Do not touch output terminals or internal electric parts while the generator is
operating.
Do not open the check door when the power switch is in the ON position. It will cause
injury by rotating parts such as cooling fans and fan belt.
Always turn the power switch to the OFF
position and stop the engine, then close
and lock OPERATION PANEL DOOR before checking or maintaining the engine or
any equipment.
Always be sure to use “Lifting Hook” when lifting up the generator. Using other parts
when lifting up the generator could cause the result of falling.
No persons should be under a suspended generator at all time.
10. Inspection/Maintenance