![Shindaiwa DGK20FS Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/shindaiwa/dgk20fs/dgk20fs_owners-and-operators-manual_1257721028.webp)
25
Check the fluid level, and add distilled water until it
reaches the upper level when the fluid level is near the
lower level.
Check the terminals for looseness and tighten properly.
<Note >
It is necessary to recharge the battery when the specific
gravity of the battery fluid is 1.23 or less. Request the
authorized distributor where the generator was purchased
to recharge the battery.
Replacing the Battery
Remove the battery negative (-) cable.
(Always be sure to remove the negative (-) side first. )
Remove the battery hold-down clamp.
Remove the battery positive (+) cable.
Remove the battery.
*Reverse the procedure above for installing the battery.
(First, connect the positive (+) cable of the replaced battery.)
9-1. Initial Startup/Pre-Check
CAUTION : EXPLOSION
Never use or recharge the battery if the fluid level is below the minimum level.
Do not create sparks or bring flame near the battery as it generates flammable gas.
WARNING : EXHAUST GAS POISONING
Do not operate the generator in poorly ventilated areas such as indoors or tunnels,
as the exhaust gas of the engine contains substances that are harmful to human
health.
Do not direct exhaust fumes at bystanders or buildings.
WARNING : INJURY
Always be sure to check that the breakers on load side and switches for any
equipment using the generator are at OFF before turning the breaker to ON. Also be
sure to advise personnel on the load side that power will be turned on before
operating the breaker.
Close all doors and lock them during operation.
Do not open the check door when the power switch is in the ON position. It will cause
injury by rotating parts such as cooling fans and fan belt.
Always turn the power switch to the OFF position and stop the engine, then close
and lock OPERATION PANEL DOOR before checking or maintaining the engine or
any equipment.
1
2
1
2
3
4
9. Operating Procedures
Upper Level
Lower Level
(-) Post
(
)
Post
Hold-Down
Clamp
Содержание DGK20FS
Страница 2: ......
Страница 12: ...9 4 2 Operation Panel Configuration Circuit Breaker Controller Voltage Regulator Power Switch 1 4 3 2...
Страница 51: ...48 13 Circuit Diagram...
Страница 52: ...2022 2021...