20
< Note >
If using a single-phase 120 V (between output terminals U-N/G and W-N/G), connect an
equivalent load between U-N/G and W-N/G.
If using a single-phase three-wire output terminal simultaneously with a receptacle output,
make sure that currents passing through each phase are less than the rated current of this
generator.
8-1. Checking Engine Oil
To check the engine oil, keep
the equipment in leveled
position, remove the oil level
gauge and wipe
so that no oil
remains, and then re-insert the
dipstick fully. Prior to starting
the engine, make sure to fill
the engine oil through the oil
filler until it reaches the MAX.
line.
< Note >
Wait approximately five minutes or more after stopping the engine to add oil before checking
the oil level again.
An accurate oil level reading cannot be obtained if the generator is not placed in leveled
position.
Do not overfill with oil to avoid engine damage.
(1) Types of Engine Oil
Use only API service-type
CJ-4
class.
WARNING : INJURY
Always turn the power switch to the OFF position and stop the engine, then close
and lock OPERATION PANEL DOOR before checking or maintaining the engine or
any equipment.
Do not open the check door when the power switch is in the ON position. It will cause
injury by rotating parts such as cooling fans and fan belts.
CAUTION : BURNS
Do not touch the engine and surrounding components immediately after stopping the
engine as they are still extremely hot.
CAUTION : FIRE
Always be sure to wipe up any spilled fuel or oil.
8. Pre-Operation Inspection
OK
Not
Enough
Too
Much
〇
×
×
Oil Level
Gauge
MAX
MIN
Oil Level
Gauge
Oil Filler