29
Press the Stop button to shut off the engine.
Turn the Power Switch to OFF position.
< Note >
Set the Power Switch to OFF position if the generator will not be used for a prolonged period.
If you leave the Power Switch to ON position, the standby current may drain the battery.
(2) Auto Start
The engine stops when the REMOTE START terminal opens.
Turn the Circuit Breaker on the operation panel to OFF position.
Press the Stop button to shut off the engine.
Turn the Power Switch to OFF position.
< Note >
Set the Power Switch to OFF position if the generator will not be used for a prolonged period.
If you leave the Power Switch to ON position, the standby current may drain the battery.
9-4. Protective Functions
This generator is equipped with functions to automatically stop operation when there is a
fault/malfunction during operation, and one to warn the operator of the fault location by use of
indicator lamps. Check the fault location when the engine is automatically stopped or an
indicator lamp illuminates to stop the engine.
Protection Feature List
No.
Action
Abnormality
Breaker
Trip
Engine
Automatic
Shutdown
Controller
Display
Cause
1
High Water
Temperature
Activates due to high water temperature in
the engine
Default : 212°F (100
°C)
2
Low Oil
Pressure
Activate due to low oil pressure in the
engine
Default
14 psi (0.98 x 100 kPa)
3
Insufficient
Battery Charge
Activates in battery charge Impossible
WARNING : INJURY
Do not open the check door when the power switch is in the ON position. It will cause
injury by rotating parts such as cooling fans and fan belt.
Always turn the power switch to the OFF position and stop the engine, then close
and lock OPERATION PANEL DOOR before checking or maintaining the engine or
any equipment.
CAUTION : BURNS
Do not touch the engine and surrounding components immediately after stopping the
engine as they are still extremely hot.
Hot steam gushes out from the coolant sub-tank if the generator overheats. Do not
touch the coolant sub-tank.
4
5
1
2
3
4