2-10 System Overview
No.
Name
Description
Function
<5>. /
Indicator
HDD status indicator
Read/ write: blinking in green
Other status: light off
NOTE: DO NOT move the machine when the
indicator is blinking in green. Otherwise the HDD
may be damaged by sudden shake.
<6>. Esc
Exit
Press to exit the current status to the previous
status.
<7>. Help
/
Press to enter or exit iScanHelper.
<8>. Patient
Patient
Information
Press to open/ exit patient information screen.
<9>. Probe
Probe
switch
Press to enter Probe and Exam Type Selection
screen.
<10>. Review
/
Press to review the stored images.
<11>. Report
/
Press to open or close the diagnosis reports.
<12>. End Exam
/
Press to end an exam.
<13>. iStation
/
Press to enter or exit the patient information
management system.
<14>. F1
User-defined
key
You can assign a function to the key. For details,
please refer to “11.1.6 Key Config” chapter.
<15>. Biopsy
/
Press to show or hide the biopsy guide line.
<16>. Setup
/
Press to open/close the preset menu.
<17>. Del
/
Press to delete the comment, etc.
<18>. /
Alphanumeric
keys
Same as on PC.
<19>. Dual
Dual-split
screen
Press to enter Dual mode from non-Dual mode;
Press to switch between windows in Dual mode.
<20>. Arrow
/
Press to enter or exit the arrow comment status.
<21>. Steer
/
Press to activate the steer function for linear probe.
<22>. /
Direction key
Switches the cursor resource in comment status.
To adjust audio volume of the PW spectrum when
pressing with <Fn> key.
<23>. Cine
Cine Review
Press to enter or exit the Cine Review status.
<24>. Body Mark
/
Press to enter or exit the Body Mark status.
<25>. Comment
/
Press to enter or exit the character comment
status.
<26>. Clear
/
Press to clear the comments or measurement
calipers on the screen.
<27>. Scale
/
Press to adjust image parameter of Scale.
<28>. Baseline
/
Press to adjust image parameter of Baseline.
<29>. Menu
/
Press to adjust image parameters.
Содержание DC-N2
Страница 1: ...DC N2 DC N2T DC N2S Diagnostic Ultrasound System Operator s Manual Basic Volume...
Страница 2: ......
Страница 14: ......
Страница 26: ......
Страница 56: ......
Страница 66: ......
Страница 106: ......
Страница 114: ...6 8 Display Cine Review 6 5 Preset Open Setup System Preset General to preset the cine storage length Clip length 1 60s...
Страница 142: ......
Страница 168: ......
Страница 206: ......
Страница 216: ......
Страница 221: ...P N 046 005132 00 V4 0...