MARK
Name
Default
value
Variable range
Operation/section
Data kind
Item
Details
Symbol
Diag display
main_cnt
COUNTER
SET2
MAM
0
0
–
999999
Drive,
trouble
Number of times
OPC drum, transfer drum
motor trouble counter
Number of drum motor troubles
poly_cnt
COUNTER SET2 PLM
0
0
–
999999
Optical,
trouble
Number
of
times
Polygon motor trouble counter
Number of polygon motor
troubles
high_cnt
COUNTER SET2 HLH
0
0
–
999999
Fusing,
trouble
Number
of
times
Fusing high temperature
trouble counter
Number of fusing high
temperature troubles
low_cnt
COUNTER
SET2
HLL
0
0
–
999999
Fusing, trouble
Number
of
times
Fusing low temperature trouble
counter
Number of fusing low
temperature troubles
topen_cnt
COUNTER
SET2
THO
0
0
–
999999
Fusing, trouble
Number
of
times
Thermistor
trouble
counter
Number of thermistor troubles
(open)
deve_cnt
COUNTER SET2 DVM
0
0
–
999999
Developing,
trouble
Number
of
times
Developing
motor
trouble
counter
Number of developing motor
troubles
pon_cnt
0
0
–
999999
Power
Number of times
Number of turning ON the
power (Number of power SW
ON/OFF)
y_ton_lev_nv
TONER
LEVEL
YELLOW
80
10
–
230
Developing
Control
level
Initial toner control level (Y)
Initial reference toner
concentration control level
(corrected value to humidity
rank 3)
Reference toner concentration
control level when a virgin
developing unit is installed
(Excluding the correction
element other than the
humidity correction.)
m_ton_lev_nv
TONER
LEVEL
MAGENTA
80
10
–
230
Developing
Control
level
Initial toner control level (M)
c_ton_lev_nv
TONER
LEVEL
CYAN
80
10
–
230
Developing
Control
level
Initial toner control level (C)
k_ton_lev_nv
TONER
LEVEL
BLACK
80
10
–
230
Developing
Control
level
Initial toner control level (BL)
low_temp
15
Fusing
trouble
Detection level
Low fusing temperature trouble
detection level (temperature)
high_temp
211
Fusing trouble
Detection
level
High fusing temperature
trouble detection level
(temperature)
cont_temp
PLAIN C 0-5
0
–
255
Fusing
Control
level
Fusing temperature control
level (Normal paper mode)
cont_temp_ohp
OHP C 0-5
0
–
255
Fusing
Control
level
Fusing temperature control
level OHP mode)
sleep_set
TIMEOUT
SET
SLP
30
3
–
255
Power,
fusing
Time
Sleep mode shift time set value
Sleep mode timer value
plmon_set
TIMEOUT
SET
PLM
180
30
–
240
Optical
Time
Polygon motor time-out set
value
Polygon motor time-out
(automatic stop) timer
y_std_sen
42
Picture quality
(process) correction
Control
level
Reference image density level
(Y)
Reference image density level
(Developing bias adjustment
target value)
m_std_sen
44
Picture quality
(process) correction
Control
level
Reference image density level
(M)
c_std_sen
45
Picture quality
(process) correction
Control
level
Reference image density level
(C)
k_std_sen
31
Picture quality
(process) correction
Control
level
Reference image density level
(BL)
10 – 18
SHARP SERVICE MANUAL JX8200SM [10] DIAGNOSTICS